Pulsation Control

INERTANCE can perform the pulsation study for reciprocating equipment (Pump and compressor), and design the pulsation control devices such as pulsation dampener, design for helmholtz frequency, Surge volume, Pulsation bottle, etc.

Dampener (Side branch)

Pulsation dampener has to be carefully designed as per the type of reciprocating pump, because this type as side branch is available only for narrow available range, which is helmholtz frequency. The branch pipe length & diameter is an important parameters to estimate the applicable range.
Pulsation Dampener
Pulsation Dampener

Helmholtz Frequency

Below figures are for side-branch type of pulsation dampener. This type of dampener should be carefully designed as per those target & helmholtz frequency. In case helmholtz frequency does not matched with target frequency, those control efficiency will be significantly reduced.
Helmholtz frequency design for dampener
Helmholtz frequency design for dampener

Surge Volume (In-line type)

Below figures are for in-line type of surge volume for pulsation control of reciprocating pump. Those volume has to be designed very carefully, and the height & diameter ratio has to be determined as per target pulsation criteria. The sphere shape of surge volume normally has good efficiency to reduce the pulsation amplitudes.
Surge volume type
Surge volume type

Pulsation Design

With application of control devices, those acoustic simulation can be performed as shown in below figure. INERTANCE can design the practical pulsation design to minimize the design impact of piping system during detail engineering stage.
Acoustic study with Pulsation control
Acoustic study with Pulsation control
Vibration Mechanical Analysis
Vibration Mechanical Analysis
INERTANCE has a capability regarding noise and vibration engineering, and our experts are familiar with assessment of pulsation control design for piping system. For further information, contact us at (mountain@inertance.com).
INERTANCE’s related services include;