Design Approach 1
Design Approach 1 is to perform the empirical pulsation suppression device design using proprietary and empirical analytical techniques to meet line side pulsation levels and the maximum pressure drop based on compressor normal operating condition.
Design Approach 2
Design Approach 2 is to perform the acoustic simulation and piping restraint analysis, which include the control design through the use of pulsation suppression devices and proven acoustic techniques. In case the detail design of piping system is finalized, the acoustic simulation has to be performed for system reliability. Then, the separation margin based on mechanical natural frequency has to be checked to avoid the mechanical resonance.
Design Approach 3, API 618
Design Approach 3 is to perform the mechanical analysis with forced mechanical response analysis in addition to Acoustic study. The forced mechanical response analysis for compressor cylinder as well as associated piping systems has to be performed as results of previous analysis results.
INERTANCE has a capability to select the sizing of surge volume as well as low pass filter, and the related pipe support design, where necessary.
INERTANCE has a capability regarding noise and vibration engineering, and our experts are familiar with assessment of API 618 study & Mechanical study. For further information, contact us at (mountain@inertance.com).
INERTANCE’s related services include;