2019. 10. 6.

Pipe calculator, support span length for pulsation - INERTANCE

Pipe calculator, support span length for pulsation - INERTANCE: Piping system: Pipe calculator for support design (support calculator) against running speed of reciprocaitng equipments (pulsation induced force).



Guideline for supports location

INERTANCE provides the pre-design calculator for pipe support span length against pulsation excitation from running speed of positive displacement equipment. This calculator is prepared for the initial piping support design of reciprocating compressor, to minimize the modification of the piping system due to mechanical study. After the initial piping arrangement is set-up, the final support location shall be determined by acoustic and mechanical study results.
Separation margin is defined as margin between the harmonic forcing excitation and the natural frequency of a compressor, pump or piping system element. Generally a 10% actual separation margin is available, and further margin for 10% uncertainty in natural frequency predictions. Therefore, total 20% of design separation margin is recommended.
Support Calculator for Piping System
Support Calculator for Piping System
For double acting compressor, the significant pulsation-induced forces at one and two times of rotational speed will be generated. Hence, resonance shall be avoided at these frequencies, suggesting predicted mechanical natural frequencies should be at least 20% above two times of running speed.

How to use this calculator

See below how to use this support span calculator
  1. Input the equipment operating speed (RPM).
  2. Press ‘Tab’ on keyboard to move next space.
  3. To specify the equipment type with single acting or double acting. Support span length will be calculated for single acting type based on one (1) time of running speed, for double acting type based on two (2) times of running speed.
  4. To specify the separation margin to be specified. (Typically 20% margin is recommended as per API 618 5th, para. 7.9.4.2.5.3.2)
  5. To specify the pipe support type with simply supported (S) or fixed supported (F).